EOL Test IntelligenceATE Execution Console
ATE Execution Console – 314Ah Battery Pack
Execute real-time EOL tests through MES, ATE, BMS, CAN, barcode, DMM, ACIR, IR/DCW and cycler integrations.
Program
Telecom Battery Pack Program
Product
314Ah Battery Pack
Test Plan ID
TP-314AH-EOL-001
Revision
Rev 07
Station / ATE ID
ATE-01
Status
In Test
Effective Date
26-Apr-2026
Serial Eligibility
Valid
Current Step
6 / 7
Functional Test
Test Progress
82%
Live Alarms
0
No Active Alarms
Safety State
Safe
All Interlocks Healthy
Tool Integrations
8
All Connected
Serial Scan & Eligibility
Pack Serial No.
PK-314AH-26042607
Module Serial No.
MOD-31426-04A
BMS Serial / QR
BMS-26042607-Q
QR/Barcode Valid Uniqueness Check MES Record Test Plan Assigned
MES Record ID
MES-26042607-001
MES Status
Active
Production Order
PO-2604-314AH-07
Auto Test Flow
- Traceability Verification
- Programming & Version Check
- OCV / Polarity Check
- Cell Voltage & Temperature
- ACIR / IR / DCW Safety Check
- 6Functional Test
- 7Result Capture & MES Update
Live Monitoring
Pack Voltage
52.48 V
Charge Current
12.35 A
Discharge Current
-24.18 A
SOC
82%
SOH
97.1%
Cell Delta V
18 mV
Max Temperature
36.4 °C
ACIR
0.42 mΩ
IR
1.85 mΩ
DCW Leakage
0.32 mA
IoT Status
Online
Current Step Result
Step 6 – Functional Test Running
| Parameter | Actual Value | Limit/Threshold | Source | Result | Time |
|---|---|---|---|---|---|
| Functional Switch Test | Pass | Pass | ATE | Pass | 10:42:11 |
| LED Indicator Check | OK | OK | ATE | Pass | 10:42:18 |
| Comm Heartbeat | 120 ms | ≤ 200 ms | CAN | Pass | 10:42:24 |
| Output Voltage | 52.48 V | 52.0 – 53.0 V | DMM | Pass | 10:42:31 |
| Termination Logic | Triggered | Triggered | BMS | Pass | 10:42:40 |
Test Control & Decision
Overall Auto ResultIn Progress
Completed Steps5 / 7
Pass Rate100%
Est. Time Remaining00:03:40
Execution Log
Latest 5 events| Time | Step | Step Name | Status | Message | Source | Duration |
|---|---|---|---|---|---|---|
| 10:39:02 | 4 | Cell Voltage & Temperature | Pass | All 16 cells within spec | BMS | 00:01:12 |
| 10:40:18 | 5 | ACIR / IR / DCW Safety Check | Pass | ACIR 0.42 mΩ within limit | ACIR/IR/DCW | 00:01:48 |
| 10:42:06 | 6 | Functional Test | Running | Executing test case FT-04 | ATE | 00:00:42 |
| 10:42:09 | 6 | Functional Test | Info | CAN heartbeat stable at 112 ms | CAN | — |
| 10:42:24 | 6 | Functional Test | Pass | Comm heartbeat within limit | CAN | 00:00:06 |
Safety / Alarm Status
No Active Alarms
- CAN Link Healthy
- Tester / Tools All OK
- Safety Interlock Clear